Article source:
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where
handling and installation cost are an important factor.
-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Conductor
Tinned copper wires
Separator (if available)
Insulation
Low smoke halogen free flame retardant compound
Screen
Tinned copper braid
Sheath
Low smoke halogen free flame retardant compound
|
A. Conductor B. Insulation C.Screen D. Sheath |
Nominal Voltage | 1.8/3kV |
Long-term Working Temperature | 100°C (WDZ-DCEVMP-100); 125°C (WDZ-DCEVMP-125) |
Lowest Operation Temperature | -40°C |
Minimum Bending Radius |
2 x Overall Diameter (OD≤10mm); 4 x Overall Diameter (10mm≤OD≤20mm); 6 x Overall Diameter (OD≥20mm) |
Flame Retardant | GB/T18380.1-2001; GB/T18380.3-2001 C |
Low Corrosivity (Acidity & Conductivity) | GB/T17650.1-1998; GB/T17650.2-1998 |
Halogen Free | GB/T17650.1-1998; GB/T17650.2-1998 |
Low Smoke | GB/T17651.1-1998; GB/T17651.2-1998 |
Nominal Cross- Sectional Area | Conductor Construction | Nominal Insulation Thickness | Nominal Sheath Thickness | Maximum Overall Diameter | Maximum Conductor Resistance 20°C |
mm² | No/mm | mm | mm | mm | Ω/km |
16 | 126/0.40 | 1.0 | 1.0 | 13.0 | 1.24 |
25 | 196/0.40 | 1.2 | 1.1 | 15.0 | 0.795 |
35 | 276/0.40 | 1.2 | 1.1 | 17.0 | 0.565 |
50 | 396/0.40 | 1.2 | 1.1 | 18.5 | 0.393 |
70 | 380/0.49 | 1.4 | 1.4 | 21.0 | 0.277 |
95 | 513/0.49 | 1.6 | 1.6 | 23.0 | 0.210 |
120 | 630/0.49 | 1.6 | 1.6 | 24.5 | 0.164 |
150 | 777/0.49 | 1.8 | 1.7 | 26.5 | 0.132 |